 LF100S Series
Ultra-Miniature, 1W Single Output SMT DC/DC Converters
Electrical Specifications
Specifications typical @ +25C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
* 1W Output Power * Ultra-Miniature SMT Case * 1,000 VDC Isolation * 5V, 12V & 24V Inputs * -40C to +85C Operation * 15 Standard Models * 2.0 MH MTBF Minimum * Industry Standard Pin-Out
Parameter Input Voltage Range Reverse Polarity Input Current Input Filter
Conditions 5 VDC Input 12 VDC Input 24 VDC Input
Min. 4.5 10.8 21.6
Typ. 5.0 12.0 24.0
Max. 5.5 13.2 26.4 0.3
Units VDC A
Capacitor Conditions For Vin Change of 1% Min. Typ. 1.0 1.2 60 Over Line, Load & Temp. 120 0.01 Momentary (0.5 Sec.) Conditions 60 Seconds 500 VDC 100 kHz, 1V 50 Conditions Ambient Case Min. -40 -40 -40 Free Air Convection RH, Non-condensing 95 % Min. 1,000 1,000 40 100 Typ. +25 100 140 Max. +85 +90 +125 Typ. Max. Units VDC M pF kHz Units C C C 0.02 See Model Selection Guide 120 150 5 mV P - P mV P - P mv rms % %/C Max. 3.0 1.5 Units % %
Output
Parameter Output Voltage Accuracy Line Regulation Load Regulation (Note 1) Ripple & Noise (20 MHz) (Note 2) Ripple & Noise (20 MHz) Ripple & Noise (20 MHz) Output Power Protection Temperature Coefficient Output Short Circuit
RoHS Compliant
General
Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency
Environmental
Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling
MicroPower Direct
292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com
Humidity
Physical
Case Size Case Material Weight 0.50 x 0.31 x 0.26 Inches (12.7 x 8.0 x 6.7 mm) Non-Conductive Black Plastic (UL94-V0) 0.05 Oz (1.5g) Conditions MIL HDBK 217F, 25C, Gnd Benign Conditions 5 VDC Input Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation 12 VDC Input 24 VDC Input 1.5 mm From Case For 10 Sec. All Models Min. 2.0 Min. -0.7 -0.7 -0.7 Typ. Max. 9.0 18.0 30.0 260 450 C mW VDC Typ. Max. Units MHours Units
Reliability Specifications
Parameter MTBF
Absolute Maximum Ratings
Parameter
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Input Model Number LF101S LF102S LF103S LF104S LF105S LF111S LF112S LF113S LF114S LF115S LF121S LF122S LF123S LF124S LF125S Voltage (VDC) Nominal 5 5 5 5 5 12 12 12 12 12 24 24 24 24 24 Range 4.5 - 5.5 4.5 - 5.5 4.5 - 5.5 4.5 - 5.5 4.5 - 5.5 10.8 - 13.2 10.8 - 13.2 10.8 - 13.2 10.8 - 13.2 10.8 - 13.2 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 Load Voltage Current Current Regulation Full-Load No-Load (VDC) (mA, Max) (mA, Min) (%, Max) Current (mA) 250 254 252 248 264 103 106 104 102 110 53 54 52 52 57 30 30 30 30 30 15 15 15 15 15 8 8 8 8 8 5.0 9.0 12.0 15.0 3.3 5.0 9.0 12.0 15.0 3.3 5.0 9.0 12.0 15.0 3.3 200.0 110.0 84.0 67.0 300.0 200.0 110.0 84.0 67.0 300.0 200.0 110.0 84.0 67.0 300.0 4.0 2.0 1.5 1.0 60.0 4.0 2.0 1.5 1.0 60.0 4.0 2.0 1.5 1.0 60.0 10 10 8 7 10 8 8 5 5 8 8 8 5 5 8 Output Efficiency (%, Typ) 80 78 80 81 75 81 78 81 82 75 79 77 80 80 73 Fuse Rating Slow-Blow (mA) 500 500 500 500 500 200 200 200 200 200 100 100 100 100 100
Notes: 1. Load regulation is measured for an output change of 20% to 100%. 2. When measuring output ripple, it is recommended that an external 0.33 F ceramic capacitor be placed from the +Vout pin to the -Vout pin. For noise sensitive applications, the use of 0.47 F capacitors will reduce the output ripple. 3. Operation at no-load will not damage these units. However, they may not meet all specifications. 4. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up. In this case, it is recommended that a low ESR (ESR <1.0 at 100 kHz) capacitor be mounted close to the converter. For 5V input units a 2.2 F is recommended, for 12V input units, a 1.0 F, and for 24V input units, a 0.47 F. 5. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating.
Board Layout
Derating Curve
Capacitive Load
F Max 33
Pin Connections
Pin 1 2 3 4 Description -Vin +Vin NA -Vout Pin 5 6 7 8 Description +Vout NA NA NA
MicroPower Direct
www.micropowerdirect.com
Mechanical Dimensions - 5V/12V Input
Mechanical Dimensions - 24V Input
Notes: * All dimensions are typical in inches (mm) * Tolerance x.xx = 0.01 (0.25) * Pin 1 is marked by a "dot" or indentation on the unit
292 Page Street, STE D, Stoughton, MA 02072
*
TEL: (781) 344-8226
*
FAX: (781) 344-8481
*
E-Mail: sales@micropowerdirect.com
MPD also offers a full range of compact open frame, enclosed, U-chassis and DIN Rail AC/DC power supplies. Our very wide range of models offers:
* * * * * * * * * * Nearly 2,000 Standard Models 10W to 1,000W Output Power 1 to 4 Outputs Universal Inputs Power Factor Correction International Approvals (Including Medical) Many Form Factors & Mechanical Options Robust Filtering & Protection Circuits High MTBFs Low Cost
Call us today. Whether you need a ruggedized unit for a critical industrial application or a very low cost basic model; we have the right AC/DC power supply for your application requirement. Below is a sampling of the products we offer.
Series Description Power Input Output Approvals Size
HF-15W-SPL
Miniature, single output openframe series
15W
Universal 85 - 264 VAC
5V to 48V
UL, cUL, CE
3.9 x 1.8 x 0.9 (100 x 46 x 22)
RL0402U
Medically approved 400W series in u-chassis or enclosed with built in fan.
400W
Universal 90-264 VAC Active PFC
Single & Dual Models 2V to 58V
UL, cUL, TUV, CE (Medical)
8 x 5 x 1.6 (203.2 x 127 x 40.6)
AD1072F
Very low cost Single output 72W DIN Rail mount supplies
72W
Universal 100 - 240 VAC
12V to 48V
CE
4.7 x 4.3 x 2.2 (121 x 110 x 56)
MPA320F
Compact 320W supplies include a cover with built in fan
320W
Auto-Ranging 90-132 VAC 185 - 264 VAC Passive PFC
Single & Dual Models 2V to 60V
UL, cUL, TUV, CE
6 x 4 x 1.5 (152.4 x 101.6 x 38.1)
HF60W-xL
Very low cost 60W enclosed series.
60W
Universal 85 - 264 VAC
Single, Dual & triple output models 5V to 48V
UL, cUL, CE
6.3 x 3.8 x 1.5 (160 x 98 x 39)
This is a just a small sampling of our AC/DC product range. Whatever your application requirements, give us a call or go to our website at www.micropowerdirect.com. If we don't have a standard product that fits your need, ask about product modifications. And don't forget, we also offer well over 2,000 standard DC/DC converters. Call today.
MicroPower Direct
www.micropowerdirect.com
292 Page Street, STE D, Stoughton, MA 02072
*
TEL: (781) 344-8226
*
FAX: (781) 344-8481
*
E-Mail: sales@micropowerdirect.com


▲Up To Search▲   

 
Price & Availability of LF114S

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X